Warning: file_put_contents(D:/Web/shibq.com/temp/caches/d/goods_2D3D4F09.php) [function.file-put-contents]: failed to open stream: Permission denied in D:\Web\shibq.com\includes\cls_template.php on line 198

Notice: can't write:D:/Web/shibq.com/temp/caches/d/goods_2D3D4F09.php in D:\Web\shibq.com\includes\cls_template.php on line 200

Warning: file_put_contents(D:/Web/shibq.com/temp/compiled/comments_list.lbi.php) [function.file-put-contents]: failed to open stream: Permission denied in D:\Web\shibq.com\includes\cls_template.php on line 262

Notice: can't write:D:/Web/shibq.com/temp/compiled/comments_list.lbi.php in D:\Web\shibq.com\includes\cls_template.php on line 264
美国力科DDA3000示波器力科示波器_数字示波器_示波器_电子测试仪器_北京岳立天成
美国力科DDA3000示波器力科示波器
  • 美国力科DDA3000示波器力科示波器
点击看大图
分享到:

美国力科DDA3000示波器力科示波器

  • 购买数量:
    商品总价:

其他相关排行榜

    同价位

    同品牌

    同类别


Warning: file_put_contents(D:/Web/shibq.com/temp/compiled/bought_goods.lbi.php) [function.file-put-contents]: failed to open stream: Permission denied in D:\Web\shibq.com\includes\cls_template.php on line 262

Notice: can't write:D:/Web/shibq.com/temp/compiled/bought_goods.lbi.php in D:\Web\shibq.com\includes\cls_template.php on line 264

最近浏览

商品描述

商品属性

如何购买

售后服务

  • 品名:美国力科DDA300...
  • 商品品牌:【美国力科(lecroy)】
  • 商品重量:0克
  • 上架时间:2015-08-12
  • 商品点击数:731

Vertical System

Analog Bandwidth @ 50 Ω (-3 dB) 3 GHz?
Rise Time (typical) 150 ps?
Input Channels 4?
Bandwidth Limiters 25 MHz; 200 MHz; 1 GHz?
Input Impedance 50Ω or 1 MΩ || 15 pF; 10 MΩ || 11 pF with PP005A Probe
Input Coupling 1 MΩ: AC, DC, GND; 50 Ω: DC
Maximum Input Voltage 50 Ω: 5 Vrms, 1 MΩ: 100 Vmax (peak AC: = 5 KHz + DC)
Channel-Channel Isolation 250:1 at same V/div setting, 40:1 at 3 GHz
Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)?
Sensitivity 50 Ω: 2 mV ¨C 1 V/div fully variable; 1 MΩ: 2 mV ¨C 2 V/div fully variable
DC Gain Accuracy ¡À1.5% of full scale; ¡À1% (typical)
Offset Range 50 Ω: ¡À700 mV @ 2¨C4.95 mV/div, ¡À1.5 V @ 5¨C100 mV/div, ¡À10 V @ .102¨C1 V/div, 1 MΩ: ¡À700 mV @ 2¨C4.95 mV/div, ¡À1.5 V @ 5¨C100 mV/div, ¡À20 V @ 0.102¨C2 V/div
Offset Accuracy ¡À(1.5% of full scale + 0.5% of offset value + 2 mV)
 

Horizontal System

Timebases Internal timebase common to 4 input channels; An external clock may be applied at the Auxiliary input
Time/Division Range 20 ps/div ¨C 10 s/div
Clock Accuracy <= 5 ppm
Time Interval Accuracy = 0.06 / SR + (5 ppm * Reading) (rms)
Jitter Noise Floor 2 ps rms @ 100 mV/div (typical)
Trigger and Interpolator Jitter <= 2.5 ps (typical)
Sample Rate and Delay Time Accuracy ¡À10 ppm = 10 s interval
Channel-Channel Deskew Range ¡À9 x time/div setting, 100 ms max, each channel.
External Clock 30 MHz ¨C 1 GHz; 50 Ω impedance; applied at the auxiliary input
 

Acquisition System

Single-Shot Sample Rate/Ch 10 GS/s
2 Channel Max? 20 GS/s?
Random Interleaved Sampling (RIS) 200 GS/s for repetitive signals:?
Maximum Trigger Rate 150,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time 6 ¦Ìs
Maximum Acquisition Points/Ch 50 Mpts, 100 Mpts in two channel mode.
Sequence Mode 25,000 segments
Maximum number of segments in Sequence Mode 25,000 segments
 

Acquisition Processing

Averaging Summed or Continuous averaging up to 1 million sweeps
Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x
 

Triggering System

Modes Normal, Auto, Single, and Stop
Sources Any input channel, External, Ext X10, Ext/10, or line; slope and level unique to each source (except line trigger)
Coupling DC
Pre-trigger Delay 0-10% of horizontal time scale
Post-trigger Delay 0 ¨C 10,000 divisions
Hold-off by Time up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range ¡À5 div from center
Max. Trigger Frequency, SMART Trigger Trigger Senstivity (Edge) 2 div < 3 GHz, 1 div < 2 GHz
 

Basic Triggers

Edge/ Slope/ Line Triggers when signal meets slope and level condition.
 

SMART Triggers

State or Edge Qualified Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
Dropout Triggers if signal drops out for longer than selected time between 2 ns and 20 s.
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs; (4 channels and external trigger input); Each source can be high, low, or don¡¯t care.; Trigger at start or end of the pattern.
 

SMART Triggers with Exclusion Technology

Glitch Triggers on positive or negative glitches with widths selectable from 600 ps to 20 s or on intermittent faults.
Signal or Pattern Width Triggers on positive or negative pulse widths selectable from 600 ps to 20 s or on intermittent faults.
Signal or Pattern Interval Triggers on intervals selectable between 2 ns and 20 s.
 

Disk Drive Triggers

Sector Trigger on the n'th sector pulse after index. Index and sector pulse polarity and sector pulse number are selectable.
Servo Gate Trigger on the n'th servo gate after index and every m'th thereafter. Index and servo gate pulse polarity are selectable.
PES Trigger Trigger on Position Error Signal (PES) exceeding an adjustable voltage window. Servo gate can be selected as qualifier.
Read Gate Trigger Trigger on any read gate longer than an adjustable Sector ID filed length.
 

Color Waveform Display

Type Color 10.4" flat-panel TFT-LCD with high resolution touch screen
Resolution SVGA; 800 x 600 pixels
Number of traces Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces.
Grid Styles Auto, Single,Dual, Quad,Octal, XY, Single + XY,Dual + XY
Waveform Representation Sample dots joined or dots only
 

Internal Waveform Memory

Internal Waveform Memory M1, M2, M3, M4 Internal Waveform Memory (Store full-length waveforms with 16 bits/data point) or store to any number of files limited only by data storage media.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals.?
Vertical Find Scale Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range.
 

Probes

Probes (2) PP005A standard; Optional passive and active probes available.?
Probe System: ProBus Automatically detects and supports a variety of compatible probes.
Scale Factors Automatically or manually selected depending on probe used.
 

Analog Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace¡¯s persistence data in memory
Trace Selection Activate Persistence on all or any combination of traces
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
Persistence Selections Select analog or color, or three-dimensional.
Persistence Aging Select from 500 ms to infinity
 

Setup and Waveform Storage

Front Panel and Instrument Status Store to the internal hard drive, or to a USB-connected peripheral device.
 

Processor/CPU

Processor Type Intel Pentium? P4, 2.54 GHz or better, 2 GB memory
Operating System Microsoft Windows? XP Professional
Real Time Clock Dates, hours, minutes, seconds displayed with waveform. SNTP support to synchronize to precision internet clocks.
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 8 Math/Zoom traces
 

Interface

Remote Control Via Windows Automation, or via LeCroy Remote Command Set
GPIB Port (optional) Supports IEEE ¨C 488.2
Ethernet Port 10/100BaseT Ethernet interface
USB (Host) 6 USB 2.0 ports, (2 accessable on front panel) support Windows? Compatible devices
External Monitor Port 15-pin D-Type SVGA-compatible?
Parallel Port 1 standard
 

Auxiliary Input

Signal Types Select from calibrator or control signals output on front panel
Max. Input Voltage 50 Ω: 5 V rms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)
 

Auxiliary Output

Signal Types Select from External Trigger or External Clock input on front panel
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Calibrator Signal 5 Hz ¨C 1 MHz square wave or DC level;?0.0 to 5.0 V into 50 Ω (0-1 V into 1 MΩ); or TTL volts (selectable)
Control Signals Trigger ready, trigger out, pass/fail status?
 

General

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum
 

Power Requirements

Max. Power Consumption 650 W/ 650 VA; 200¨C240 V AC at 50/60 Hz;? Automatic AC Voltage selection; Power consumption: < 800VA
 

Environmental and Safety

Temperature (Operating) +5 ¡ãC to +40 ¡ãC including CD-ROM drive
Temperature (Non-Operating) -20¡ãC to +60¡ãC
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +30 ¡ãC. Upper limit derates to 25% relative humidity (non-condensing) at +40¡ãC
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) up to 10,000 ft (3048 m) at or below +25¡ãC
Altitude (Non-Operating) up to 40,000 ft (12,192 m)
Random Vibration (Operating) 0.31 g rms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 g rms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Physical Dimensions

Dimensions (HWD) 264 mm x 397 mm x 491 mm; 10.4" x 15.6" x 19.3" (height excludes feet)
Weight 18 kg; 39 lbs?
Shipping Weight 24 kg; 53 lbs
 

Certifications

Certifications CE compliant, UL and cUL listed; conforms to EN 61326-1, EN 61010-1, UL 3111-1, and CSA C22.2 No. 1010.1?
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services.?
 

Maximum Performance
Since their inception, Disk Drive Analysis (DDA) Series oscilloscopes have helped data storage design engineers improve the time to market of new products and accelerated understanding and failure analysis on existing drives. LeCroy continues that tradition with its powerful Disk Drive Analysis toolset, enabling you to capture, view, and analyze the waveshape of high-speed, complex drive signals with speed and integrity. LeCroy's X-Stream architecture integrates SiGe "digitizer on a chip" technology and a specialized high-speed streaming bus design to transfer data from the ADC to a proprietary acquisition memory. The X-Stream architecture enables disk drive engineers to quickly, easily, and accurately measure and analyze disk drive signals.

The DDA 5005A is designed for signal fidelity, whole track acquisition and analysis for read channel, media noise analysis, and head parametrics with the longest acquisition memory standard. The DDA 3000 provides the same measurement capability at a lower bandwidth. This unique product has the convenience of selectable 50 O or 1 MΩ inputs.

 

Excellence in Head, Disk,Track, and Noise Analysis
The DDA Series analyzers incorporate the tools to make you the most efficient. The standard 100 Mpts of capture memory in the DDA 3000 (2 channel mode) and DDA 5005A XXL provides 5 milliseconds of single-shot 20 GS/s capture on two channels, allowing multiple drive sectors to be acquired at once.

 

 

Long Memory and Flexibility in Finding Problems
Acquire a head signal up to 5 GHz, and then QuickZoom it from the front panel. The DDA copies and expands the drive signal automatically. Simply scroll horizontally and vertically to examine any sector. Multiple zooms let you view up to eight separate areas of the head signal; each zoom comes in a distinct color. You can measure the time between two events accurately with horizontal and vertical cursors. Disk drive parameters let you characterize the pulse width variation or signal¨Cto¨Cnoise ratio across a selectable region. Failure Analysis engineers can store and recall golden waveforms and panel setups to compare problem drives with the known good drives. Analog¨Cto¨Cdigital converters running at speeds up to 20 GS/s ensure the right sensitivity to measure today's high-speed read channels. In every DDA, you can run your customer-developed scripts to view the captured signal with the filters matched to your channel and media. Custom user scripts can be created in MATLAB, Mathcad, Visual Basic, or even Excel.

 

 

Exceptional Trigger Performance
Disk Triggers allow you to set up a series of events in the signal that then cause a trigger. For example, qualify the signal on the index signal and then capture all the sectors of information on the track. As memory is increased in the DDA, more sectors can be captured, with up to 50 picosecond/sample time resolution. Up to 25,000 sectors of data can be gathered with the DDA 3000 or DDA 5005A XXL.

 

 

Natural Graphical Interface
One press of the DDA button takes you directly to the Disk Drive Analyzer features. The familiar controls on the front panel, coupled with a natural, context-sensitive graphical user-interface, reacts quickly to your commands. Functionality is exactly where you expect it to be. If you have questions, context-sensitive on-line help gives immediate assistance.

 

 

Cursors
Cursors let you measure time and amplitude points on the disk waveforms. You can measure the time between gate and signal across two different channels. Different cursor modes are easily recalled and set. They are easily accessed from the front panel or the graphical user interface. Set up basic time or amplitude cursors on a single waveform, or choose to use independent cursors on different waveforms.

 

 

ProLink® Signal Inputs (DDA 5005A Analyzer)
ProLink inputs provide a high integrity, high bandwidth interchangeable interface to SMA or BNC cables, probes, and accessories. ProLink supports ProBus for direct, automatic control of LeCroy probes and accessories. The optional AP-1M adapter provides Hi-Z input.

 

 

Flexible Connectivity
The DDA Series comes complete with a 100Base-T/10Base-T Ethernet connection and a built-in hard drive for waveform storage. At the press of a button, you can even e-mail the measurement result and waveform display to other engineers or to your notebook. Attach any USB device for extended connectivity for network printing, or for attaching additional storage or pointing devices.

 

 

DMOD Option
The DMOD math function adds seven new processing functions (Amplitude , Phase, Real, Imaginary, Complex, Frequency and Wideband AM). These demodulated waveforms are useful for many purposes:
  • To analyze FM or PM modulated signals
  • To study unwanted variations in any of these domains (frequency or phase "noise" analysis)
  • To study unwanted systematic "pickup" or interference on either transmitted RF, or on oscillators, phase-lock-loops etc.
  • To study instantaneous power
  • To study envelopes of amplitude modulated signals with variable bandwidth.
Only two of the result types are rescalable, Frequency (FM) and Phase (PM), since the magnitudes of these projections cannot be known beforehand. All of the other results are scaled on the vertical scale of the original digitized carrier waveform.

 

There are no parameters specific to the Demodulation math option.

如何购买
售后服务

用户评论

(共0条评论)

  • 暂时还没有任何用户评论
总计 0 个记录,共 1 页。
第一页 上一页 下一页 最末页
用户名: 匿名用户
E-mail:
评价等级:
评论内容:
验证码: captcha